Page #851 background image
11/2006 List of Action Numbers
3-851
© Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), Edition 11/2006
No. 115
No. 116
No. 117
No. 118
No. 119
No. 120
Explanation The event is triggered by the positive PLC edge of the "Repos-Mode-Edge"signal.
Cause The channel is active (program running, block search, loading machine data)
Remedy Abort the program with the Reset key or stop the program (not with block search, loading
machine data).
Explanation Activate tool-management commands (Ch. VDI signal).
Cause The NCK channel is in a state other than "ready".
Remedy Abort the program or process with the Reset key or wait for end of program.
Explanation Deactivate tool-management commands (Ch. VDI signal).
Cause The NCK channel is in a state other than "ready".
Remedy Abort the program or process with the Reset key or wait for end of program.
Explanation Selection of desired safety limitations (SGE) (always allowed).
Cause -
Remedy -
Explanation Stop run, i.e., the NCK has automatically stopped at an OPI-defined block
Cause 1. SFC is not in automatic mode
Remedy -
Explanation Rapid lift with a single axis
Cause The axis is not controlled by the PLC
Remedy -

Other manuals for Siemens Simodrive 611

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Simodrive 611 and is the answer not in the manual?

Siemens Simodrive 611 Specifications

General IconGeneral
BrandSiemens
ModelSimodrive 611
CategoryMedia Converter
LanguageEnglish

Related product manuals