02.00 Parameter list
SIEMENS AG 6RX1700-0AD76 11-81
SIMOREG DC Master Operating Instructions
PNU Description Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
r959 Alarm parameter 7
Parameter alarms 7 (TB alarms 1)
If one of the alarms between 97 and 112 is generated, the corresponding
segment in the display lights up.
100 99 98 97
101
102
103
104
105106107108109110111112
Ind: None
Type: V2
P052 = 3
r960 Alarm parameter 8
Parameter alarms 8 (TB alarms 2)
If one of the alarms between 113 and 128 is generated, the corresponding
segment in the display lights up.
116 115 114 113
117
118
119
120
121122123124125126127128
Ind: None
Type: V2
P052 = 3
r967 Display of control word 1
Visualization parameter for control word 1 (bits 0-15)
Identical to r650 (control word 1)
Ind: None
Type: V2
P052 = 3
r968 Display of status word 1
Visualization parameter for status word 1 (bits 0 - 15)
Identical to r652 (status word 1)
Ind: None
Type: V2
P052 = 3
11.46 Resetting and storing parameters,
list of existing and modified P and r parameters
P970
*
Restore factory setting
Reset parameters to factory setting (default)
0: Parameter reset: All parameters are reset to their original
values (factory setting). This parameter is then automatically
reset to 1.
1: No parameter reset
Note: Function can also be selected by setting P051=21.
0 to 1
1
Ind: None
FS=1
Type: O2
P052 = 3
P051 = 40
Offline
P971
*
EEPROM transfer
Transfer of parameter values from RAM to EERPROM on switchover from
0 to 1.
It takes approximately 15s to process all values. The PMU remains in value
mode for this period.
0 to 1
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Offline
r980 List of existing parameter numbers, start
Visualization parameter for displaying the first 100 parameter numbers in
the P or r parameter range (0 to 999). The parameter numbers are listed in
ascending sequence.
Repetition of a number over several indices means that there are no further
parameter numbers in the 0 to 999 range.
The list is continued at the parameter whose number is displayed under
index 101.
See also r989
Ind: 101
Type: O2
P052 = 3
r981 List of existing parameter numbers, continuation
See r980.
Ind: 101
Type: O2
P052 = 3
r982 List of existing parameter numbers, continuation
See r980.
Ind: 101
Type: O2
P052 = 3
r983 List of existing parameter numbers, continuation
See r980.
Ind: 101
Type: O2
P052 = 3
r984 List of existing parameter numbers, continuation
See r980.
Ind: 101
Type: O2
P052 = 3