Parameter list 02.00
11-88 SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
PNU Description Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
11.52 Binector/connector converter for serial interfaces [SW 1.4 and later]
U116
(2116)
*
Source for binector/connector converter for GSST1 [SW1.4 and later]
Binectors which must be converted to connector K2020
i001: 1
st
binector (bit 0)
i002: 2
nd
binector (bit 1)
...
i016: 16
th
binector (bit 15)
Settings:
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: 16
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U117
(2117)
*
Source for binector/connector converter for GSST2 [SW1.4 and later]
Binectors which must be converted to connector K6020
i001: 1
st
binector (bit 0)
i002: 2
nd
binector (bit 1)
...
i016: 16
th
binector (bit 15)
Settings:
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: 16
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U118
(2115)
*
Source for binector/connector converter for GSST3 [SW1.4 and later]
Binectors which must be converted to connector K9020
i001: 1
st
binector (bit 0)
i002: 2
nd
binector (bit 1)
...
i016: 16
th
binector (bit 15)
Settings:
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: 16
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U119
(2119)
*
Parameters for the Trace function of SIMOVIS [SW1.4 and later]
This parameter is a setting for the exchange of process data between
SIMOVIS and the SIMOREG converter. It must not be changed!
11.53 Mathematical functions
Parameters apply only if optional S00 technology software is installed
Adder / subtractor
The 3 operands of a function block are selected by 3 indices each of a parameter.
U120 to U131:
The connectors selected via indices i001 and i002 are added, the connector selected via index i003 is subtracted.
U120 to U122 [SW 1.8 and later]:
The connectors selected via indices i004 and i005 are added, the connector selected via index i006 is subtracted.
The result is limited to -200.00 to +199.99% and applied to the connector stated.
U120
(2120)
*
S00
Operands for 1st adder / subtractor (result = K9120) FB 20
Operands for 13th adder / subtractor (result = K9132) FB 32
(SW 1.8 and later)
0 = Connector K0000
1 = Connector K0001
etc.
All connector
numbers
1
Ind:
3
[up to
SW1.7]
6
[SW 1.8 and
later]
FS=0
Type: L2
P052 = 3
P051 = 40
off-line

Table of Contents