02.00 Parameter list
SIEMENS AG 6RX1700-0AD76 11-111
SIMOREG DC Master Operating Instructions
PNU Description Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
U360
(2360)
*
S00
Source for input signals, OR element 11 (output = B9390) FB 160
As for U350
All binector numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U361
(2361)
*
S00
Source for input signals, OR element 12 (output = B9391) FB 161
As for U350
All binector numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U362
(2362)
*
S00
Source for input signals, OR element 13 (output = B9392) FB 162
As for U350
All binector numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U363
(2363)
*
S00
Source for input signals, OR element 14 (output = B9393) FB 163
As for U350
All binector numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U364
(2364)
*
S00
Source for input signals, OR element 15 (output = B9394) FB 164
As for U350
All binector numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U365
(2365)
*
S00
Source for input signals, OR element 16 (output = B9395) FB 165
As for U350
All binector numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U366
(2366)
*
S00
Source for input signals, OR element 17 (output = B9396) FB 166
As for U350
All binector numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U367
(2367)
*
S00
Source for input signals, OR element 18 (output = B9397) FB 167
As for U350
All binector numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U368
(2368)
*
S00
Source for input signals, OR element 19 (output = B9398) FB 168
As for U350
All binector numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U369
(2369)
*
S00
Source for input signals, OR element 20 (output = B9399) FB 169
As for U350
All binector numbers
1
Ind: 3
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
EXCLUSIVE OR elements with 2 inputs each
The input signals selected via the 2 indices of the parameter are combined in an EXCLUSIVE OR (XOR) operation and the result applied
to the specified binector.
U370
(2370)
*
S00
Source for input signals, XOR element 1 (output = B9195) FB 170
i001 Source for input 1
i002 Source for input 2
Settings:
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U371
(2371)
*
S00
Source for input signals, XOR element 2 (output = B9196) FB 171
As for U370
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U372
(2372)
*
S00
Source for input signals, XOR element 3 (output = B9197) FB 172
As for U370
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U373
(2373)
*
S00
Source for input signals, XOR element 4 (output = B9198) FB 173
As for U370
All binector numbers
1
Ind: 2
FS=0
Type: L2
P052 = 3
P051 = 40
Offline