Parameter list 02.00
11-120 SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
PNU Description Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
Technology controller: Set I component
When the state of the binector selected in U506 switches from log. "0" to "1", the I component of the technology controller is set to the
value parameterized in U505.
With this function it is possible, for example, to use the same signal (binector) to control controller enabling commands and setting of the
I component.
U505
(2505)
*
S00
Source for setting value for I component FB 114
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U506
(2506)
*
S00
Source for control bit "Set I component" FB 114
0 = binector B0000
1 = binector B0001
etc.
All binector numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
Technology controller: Output, limitation
U507
(2507)
*
S00
Source for variable positive limit FB 114
After multiplication with U508, the contents of the selected connector act as
a positive limit for the technology controller output.
0 = connector K0000
1 = connector K0001
etc.
Note:
If the selected connector contains a negative value, a negative maximum
value is applied to the output of this limiter stage.
All connector
numbers
1
Ind: None
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
U508
(2508)
S00
FDS
Positive limit for output of technology controller FB 114
See also U507
0.0 to 199.9
[%]
0.1
Ind: 4
FS=100.0
Type: O2
P052 = 3
P051 = 40
Online
U509
(2509)
*
S00
Source for variable negative limit FB 114
After multiplication with U510, the contents of the selected connector act as
a negative limit for the technology controller output.
0 = connector K0000
1 = connector K0001
etc.
Note:
If the selected connector contains a positive value, a positive minimum
value is applied to the output of this limiter stage.
Note:
Connector K9252 contains the positive limiting value with inverted sign
generated by U507 and U508. By setting U509=9252 and U510=100.00,
therefore, it is possible to set the negative and positive limits symmetrically.
All connector
numbers
1
Ind: None
FS=9252
Type: L2
P052 = 3
P051 = 40
Offline
U510
(2510)
S00
FDS
Negative limit for output of technology controller FB 114
See also U509
0.0 to 199.9
[%]
0.1
Ind: 4
FS=100.0
Type: O2
P052 = 3
P051 = 40
Online
U511
(2511)
*
S00
Source for variable weighting factor for output FB 114
After multiplication with U512, the contents of the selected connector act as
a weighting factor for the technology controller output.
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=1
Type: L2
P052 = 3
P051 = 40
Offline
U512
(2512)
S00
FDS
Weighting factor for output FB 114
See also U511
-100.0 to 100.0
[%]
0.01
Ind: 4
FS=100.0
Type: I2
P052 = 3
P051 = 40
Online