Connectors and binectors 02.00
12-24 SIEMENS AG 6RX1700-0AD76
SIMOREG DC Master Operating Instructions
Binector Name, description Function
diag., Sheet
Messages
B0160
0=AUS1 or AUS3 active, 1=no AUS1 and no AUS3 is pending
G180
B0161
B0160 inverted
G180
B0164
1 = n < n
min
[SW 1.4 and later]
G212
B0165
B0164 inverted [SW 1.4 and later]
G212
B0166
1 = Voltage at power section is active [SW 1.4 and later]
B0167
B0166 inverted [SW 1.4 and later]
B0168
1 = E-Stop is active [SW 1.4 and later]
B0169
B0168 inverted [SW 1.4 and later]
Motor interface
B0180
1 = Monitoring brush length (Terminal 211=0) has responded, condition for A025 or F025 fulfilled
G186
B0181
1 = Monitoring bearing state (terminal 212=1) has responded, condition for A026 or F026 fulfilled
G186
B0182
1 = Monitoring motor fan (terminal 213=0) has responded, condition for A027 or F027 fulfilled
G186
B0183
1 = Monitoring motor temperature (terminal 213=0) has responded, condition for A028 or F028 fulfilled
G186
Temperature sensor inputs [SW 1.6 and later]
B0184
1=Alarm motor temperature 1
G185
B0185
1=Alarm motor temperature 2
G185
Alarms [SW 1.6 and later]
B0186
1=Alarm A037 (I2t motor) is pending
B0187
1=Alarm A039 (I2t power section) is pending
B0188
1=Alarm A067 (heat sink temperature) is pending
B0189
1=Alarm A067 (device fan) is pending
Torque limitation, current limitation, current controller, armature gating unit
B0192
Speed limitation controller: Positive speed limit reached [SW 1.8 and later] G160
B0193
Speed limitation controller: Negative speed limit reached [SW 1.8 and later] G160
B0194
Current limitation: Positive current limit reached [SW 1.8 and later] G161
B0195
Current limitation: Negative current limit reached [SW 1.8 and later] G161
B0196
α
G
limit reached [SW 1.8 and later]
G162
B0197
α
W
limit reached [SW 1.8 and later]
G162
B0200
Current limitation active G161
B0201
Speed limiting controller active G160
B0202
Upper torque limitation active G160
B0203
Lower torque limitation active G160
B0204
Torque or current limitation active or current controller at limitation G162
Speed controller
B0205
Speed controller enabling by sequencing control G152
Setpoint processing, ramp-function generator
B0206
Limitation after ramp-function generator (setpoint limitation) has responded G136
B0207
Ramp-function generator output = 0 (y = 0) G136
B0208
Ramp-function generator, ramp-up G136
B0209
Ramp-function generator, ramp-down G136
B0210
1 = no direction of rotation enabled G135
B0211
Ramp-function generator: Enable setpoint (1 = setpoint enabled) [SW 1.6 and later] G136