02.00 Start-Up
SIEMENS AG 6RX1700-0AD76 7-23
SIMOREG DC Master Operating Instructions
Response identifier
Jo
identifier
Meaning
positive negative
0No job0
1 Request parameter value (word or double word) 1 or 2
2 Change (write) parameter value (word) 1
3 Change (write) parameter value (double word) 2
4 Request descriptive element 3
5 Reserved -
6 Request parameter value (array) (word or double word) 4 or 5
7 Change parameter value (array word) 4
8 Change parameter value (array double word) 5
9 Request number of array elements 6
10 Reserved -
11 Change parameter value (array double word) and store in EEPROM 5
12 Change parameter value (array word) and store in EEPROM 4
13 Change parameter value (double word) and store in EEPROM 2
14 Change parameter value (word) and store in EEPROM 1
15 Request text 15
7 or 8
If the drive was unable to execute the job, then it responds with a fault identifier. It returns a fault
code as a parameter value. This code describes the fault in greater detail as defined in the following
list:
Fault code Meaning
0 Illegal parameter number (PNU) PNU does not exist
1 Parameter value is read-only value Visualization parameter
2 Lower or upper value limit violated
3 Faulty subindex
4 Parameter is not indexed (not an array)
5 Incorrect data type
6 Parameter value can only be reset
7 Descriptive element is read-only element
8 PPO write (acc. to "Information Report") is not available
9 Parameter description is not available
10 Incorrect access level
11 No parameterization enable (P927)
12 Code word missing Key parameter P051 incorrect
13 Text cannot be read cyclically
15 Text does not exist
16 PPO write missing
17 Incorrect operating state
19 Value cannot be read cyclically
101 Parameter number is currently deactivated
102 Channel is not wide enough
103 Incorrect number of PKW Applies only to serial interfaces
104 Parameter value is not legal With BiCo selection parameters
105 Indexed parameter