EasyManua.ls Logo

Siemens SIMOTICS XP 1LG6 - Page 40

Siemens SIMOTICS XP 1LG6
75 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Electrical connection
Explosion-protected machines
112 56100000002002, 01/2016
Table 6-2 Thread sizes in the aluminum terminal box
Frame size
Type
Type of protection /
Zone
Standard thread
Additional
thread with
mounting parts
Size
Num
ber
Size
Num
ber
63 ... 90 1LA7
1LA9
1MA7
Increased safety "e" M 16 x 1.5
M 25 x 1.5
1
1
- -
Non sparking "n"
Zone 21
Zone 21
80 ... 90 1MB1
Non-sparking "n"
M 16 x 1.5
M 25 x 1.5
1
1
- -
Zone 21
Zone 21
100 ... 132 1LA7
1LA9
1MA7
Increased safety "e"
M 32x1.5 4 - -
Non sparking "n"
Zone 21
Zone 22
100 ... 132 1MB1
Non sparking "n"
M 32x1.5 2 M 16x1.5 1
Zone 21
Zone 22
160 1LA7
1LA9
1MA7
Increased safety "e"
M 40x1.5 4 - -
Non sparking "n"
Zone 21
Zone 22
160 1MB1
Non sparking "n"
M 40x1.5 2 M 16x1.5 1
Zone 21
Zone 22
180 1LA5 Zone 21 M 40x1.5 2 M 16x1.5 1
Zone 22