Table 8-1 Electrical influences
Electrical fault characteristics
Machine will not start up
Machine starts up reluctantly
Rumbling noise during startup
Rumbling noise during operation
Overheating during no-load operation
Overheating when under load
Overheating of individual winding sections
Possible causes of faults
Interruption of a phase in
Check switches and supply lines
X
Interruption of a phase in
the supply line after switch-
Check switches and supply lines
X
Check power supply conditions
Check power supply conditions
X
Stator winding incorrectly
Check winding connections
X
Winding short circuit or
phase short circuit in stator
winding
Measure the winding resistanc-
es and insulation resistances,
repair after consultation with
Incorrect direction of rota-
Check connections
(1) As well as eliminating the cause of the fault (as described under "Remedial
measures"), you must also rectify any damage the machine may have suffered.