CAUTION: A proper programming of the parameters of the VFD is 
of  the  utmost  importance.  Please  read  and  understand  the  VFD 
manufacturer's instructions manual. Use the data on the motor nameplate. 
VFD  Programming  should  be  performed  by  qualified  personnel  only.  For 
further  information  and/or  technical  support,  please  consult  your  local 
SIEMENS sales office. 
 
 CAUTION: If  the  motor is equipped  with  tachometer, safety  and 
connection  instructions  from  the  tachometer  manufacturer  shall  be 
addressed before starting the motor for the first time. 
 
 Measures to take when commissioning explosion-
proof  Motors. 
 
  After installation or inspections, the following measures are 
recommended for normal start-up of the machines:  
 ● Start the machine without a load; to do this, close the motor starter 
  protector and do not switch the machine off prematurely.  
 ● You should limit how often you switch the machine off while it is 
  starting up and still running at a slow speed, for checking the 
  direction of rotation or the required dimensions, for example.  
 ● Allow machines to reach a standstill before switching them back on.  
 
Operation   9 
 
  Before  starting  the  motor  for  the  first  time  make  sure  that  all  the 
previously stated recommendations are fulfilled. 
 WARNING: Before starting the motor, check that all the screws and 
rotating parts are correctly positioned and tightened. The use of protective 
covers  in  rotating  parts  is  suggested.  Make  sure  that  the  electrical 
connections are correct, and that leads are firmly attached and sufficiently 
insulated for the operating voltage levels. 
 
  If  a  reduced  voltage  start  method  is  to be  used,  it  is  important to 
consider  that  the  torque  output  will  be  lower  in  the  same  proportion.  For 
further information and/or technical support on our motor starting solutions, 
please consult your local SIEMENS sales office.