Par. No.
Name
Unit
Data type
r0037[0...1
9]
Power unit temperatures
°C
Float
Description: Displays the temperatures in the power unit.
Index:
[0]: Inverter maximum value
[1]: Depletion layer maximum value
[2]: Rectifier maximum value
[3]: Air intake
[4]: Interior of power unit
[5]: Inverter 1
[6]: Inverter 2
[7]: Inverter 3
[8]: Inverter 4
[9]: Inverter 5
[10]: Inverter 6
[11]: Rectifier 1
[12]: Rectifier 2
[13]: Depletion layer 1
[14]: Depletion layer 2
[15]: Depletion layer 3
[16]: Depletion layer 4
[17]: Depletion layer 5
[18]: Depletion layer 6
[19]: Cooling unit liquid intake
Dependency: Refer to A01009
Notice: Only for internal Siemens troubleshooting.
Note:
The value of -200 indicates that there is no measuring signal.
r0037[0]: Maximum value of the inverter temperatures (r0037[5...10]).
r0037[1]: Maximum value of the depletion layer temperatures (r0037[13...18]).
r0037[2]: Maximum value of the rectifier temperatures (r0037[11...12]).
The maximum value is the temperature of the hottest inverter, depletion layer, or rectifier.
r0079[0...1
]
Torque setpoint total Nm Float
Description:
Displays and connector output for the torque setpoint at the output of the speed controller (before
clock cycle interpolation).
Index:
[0]: Unsmoothed
[1]: Smoothed
r0296
DC link voltage undervoltage threshold
V
U16
Description:
Threshold to detect a DC link undervoltage.
If the DC link voltage falls below this threshold, the drive unit is tripped due to a DC link undervoltage condi-
tion.
Note: The value depends on the device type and the selected device rated voltage.
r0297
DC link voltage overvoltage threshold
V
U16
Description:
If the DC link voltage exceeds the threshold specified here, the drive unit is tripped due to DC link
overvoltage.
Dependency: Refer to F30002.
r0311
Rated motor speed
rpm
Float
Description: Displays the rated motor speed (rating plate).