1-17
Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
11.02 1 Alarms
1015 Channel %1 axis %2 system error %3
Parameters: %1 = Channel number
%2 = Axis number
%3 = System error number
Definitions: With this alarm, internal alarm states are displayed that, in conjunction with the trans-
ferred error number, provide information on the cause and location of the error. Especially
with parameter %3 (system error number) = 840001 = Problem with tool management,
the identification for the axis is not contained in parameter %2, but instead, further infor-
mation for the diagnostics (= Status of the data management/magazine no./location no./T
no.)
Reactions: - Alarm display.
- Interface signals are set.
- Local alarm reaction.
- Channel not ready.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Program Continuation: Clear alarm with the RESET key. Restart part program
1016 Channel %1 axis %2 system error %3
Parameters: %1 = Channel number
%2 = Axis number
%3 = System error number
Definitions: With this alarm, internal alarm states are displayed that, in conjunction with the trans-
ferred error number, provide information on the cause and location of the error.
Reactions: - Alarm display.
- Interface signals are set.
- Local alarm reaction.
- Mode group not ready.
- Channel not ready.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Program Continuation: Clear alarm with the RESET key in all channels of this mode group. Restart part program.
1017 Channel %1 axis %2 system error %3
Parameters: %1 = Channel number
%2 = Axis number
%3 = System error number
Definitions: With this alarm, internal alarm states are displayed that, in conjunction with the trans-
ferred error number, provide information on the cause and location of the error.
Reactions: - Alarm display.
Remedy: Make a note of the error text and contact Siemens AG A&D MC, Hotline (tel./fax: see
alarm 1000)
Program Continuation: Clear alarm with the Delete key or NC START.
1018 Floating point arithmetic error in channel %1 task %2 station %3 FPU state %4 %4
Parameters: %1 = Channel number
%2 = Task ID
%3 = Station priority
%4 = FPU status
Definitions: The floating point unit of the processor has found a computational error.