1 Alarms 11.02
1-30
Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Reactions: - Alarm display.
- Interface signals are set.
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
Remedy: Define a correct, unique axis assignment.
Program Continuation: Switch control OFF - ON.
4016 Axis %1 already used by NCU %2
Parameters: %1 = Machine axis index
%2 = NCU number
Definitions: An attempt was made to apply setpoints to one axis from several NCUs. Only occurs with
the NCU link system
Reactions: - Alarm display.
- Interface signals are set.
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
Remedy: Define a correct, unique axis assignment.
Program Continuation: Switch control OFF - ON.
4017 Axis container %1, location %2 already used by NCU %3
Parameters: %1 = Axis container number
%2 = Axis container location
%3 = NCU number
Definitions: A multiple reference to the axis container location has been made via the logical axis table
(machine data: MN_AXCONF_LOGIC_MACHAX_TAB). With the NCU link, the multiple
reference may also have been made by another NCU in the NCU group.
Example: Container1 location1 was referenced twice incorrectly
MN_AXCONF_LOGIC_MACHAX_TAB[0] = CT1_SL1
MN_AXCONF_LOGIC_MACHAX_TAB[6] = CT1_SL1
Reactions: - Alarm display.
- Interface signals are set.
- NC not ready.
- Channel not ready.
- NC Start disable in this channel.
- NC Stop on alarm.
Remedy: Correct and complete the container location assignments. Check the machine data for the
logical axis assignment table (MN_AXCONF_LOGIC_MACHAX_TAB)
Program Continuation: Switch control OFF - ON.
4018 Axis container %1, location %2 not used by any channel
Parameters: %1 = Axis container number
%2 = Axis container location
Definitions: The container location is not referenced by any channel.
Reactions: - Alarm display.
- Interface signals are set.
- NC not ready.
- NC Start disable in this channel.
- NC Stop on alarm.

Other manuals for Siemens Sinumerik 840D Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Sinumerik 840D Series and is the answer not in the manual?

Siemens Sinumerik 840D Series Specifications

General IconGeneral
AxesUp to 31 axes
Power Supply24 V DC
Control TypeCNC
InterfaceEthernet, PROFIBUS
DisplayTFT color display
PLCIntegrated PLC (programmable logic controller)
Operating Temperature0°C to 45°C
Relative HumidityUp to 95% (non-condensing)
Max. Number of ChannelsUp to 10 channels