1-31
Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
11.02 1 Alarms
Remedy: Correct and complete the container location assignments. Check machine data
MC_AXCONF_MACHAX_USED and MN_AXCONF_LOGIC_MACHAX_TAB.
Program Continuation: Switch control OFF - ON.
4019 Axis container %1 advance not allowed with current status of NCU %2
Parameters: %1 = NCU number
%2 = Axis container number
Definitions: This error only occurs with direct advancing of the container. With direct container
advancing, only one channel is allowed to activate the NC language command for
advancing the container. In order to ensure this, the other channels must have the reset
status and the axes must be stationary.
With NCU link, the above condition applies to all channels of the NCU group.
Error parameters:
1 : NC Ready missing
16: At least one other channel is active
35: AXCT axis is active following axis/spindle
36: AXCT axis is active leading axis
39: Axis/spindle disable active
40: Overlaid motion active for AXCT axis
41: Axis replacement active for AXCT axis
42: Interpolator active for one axis container axis
46: Rotating spindle with different Ipo cycle of NCUs
47: New-Config active
Reactions: - Alarm display.
- Interface signals are set.
- NC Stop on alarm.
- Interpreter stop
- NC Start disable in this channel.
Remedy: The program must be canceled with Reset and the zero offset deselected before activat-
ing the axis container switch.
Program Continuation: Clear alarm with the RESET key. Restart part program
4020 Identifier %1 used several times in machine data %2
Parameters: %1 = String: Name of identifier
%2 = String: MD identifier
Definitions: When determining a name in the NCK tables (arrays) for: machine axes, Euler angles,
direction vectors, interpolation parameters and intermediate point coordinates, an identi-
fier has been used that is already in the control.
Reactions: - Alarm display.
- Interface signals are set.
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Select for the identifier to be
entered a character string that is not yet used in the system (max. 32 characters).
Program Continuation: Clear alarm with the RESET key in all channels of this mode group. Restart part program.

Other manuals for Siemens Sinumerik 840D Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Sinumerik 840D Series and is the answer not in the manual?

Siemens Sinumerik 840D Series Specifications

General IconGeneral
AxesUp to 31 axes
Power Supply24 V DC
Control TypeCNC
InterfaceEthernet, PROFIBUS
DisplayTFT color display
PLCIntegrated PLC (programmable logic controller)
Operating Temperature0°C to 45°C
Relative HumidityUp to 95% (non-condensing)
Max. Number of ChannelsUp to 10 channels