EasyManuals Logo

Siemens Sinumerik 840D Series User Manual

Siemens Sinumerik 840D Series
622 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
1 Alarms 11.02
1-32
Siemens AG, 2002. All rights reserved
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
4021 Channel %1 identifier %2 used several times in machine data %3
Parameters: %1 = Channel number
%2 = String: Name of identifier
%3 = String: MD identifier
Definitions: To determine the name in the channel-specific tables for geometry axes and channel
axes an identifier already existing in the control has been used.
Reactions: - Alarm display.
- Interface signals are set.
- NC not ready.
- Mode group not ready, also effective for single axes
- NC Start disable in this channel.
- NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Select for the identifier to be
entered a character string that is not yet used in the system (max. 32 characters).
Program Continuation: Switch control OFF - ON.
4022 Axis container %3 switch not allowed: ext. zero offset active channel %1 axis %2
Parameters: %1 = Channel
%2 = Axis/spindle
%3 = Axis container number
Definitions: The axis container switch enable cannot be given because an external zero offset is
active.
Reactions: - Alarm display.
- Interface signals are set.
- NC Stop on alarm.
- Interpreter stop
- NC Start disable in this channel.
Remedy: The program must be aborted with the RESET key and the external zero point offset
deselected before the container is advanced.
Program Continuation: Clear alarm with the RESET key. Restart part program
4023 Axis container %1 switch not allowed, axis container %2 switch active
Parameters: %1 = Axis container
%2 = Axis container
Definitions: Only one axis container can be rotated at a time.
Reactions: - Alarm display.
- Interface signals are set.
- NC Stop on alarm.
- Interpreter stop
- NC Start disable in this channel.
Remedy: Program must be canceled with Reset and the program sequences (NCUs, channels)
must be synchronized such that only one axis container switch is active at a time.
Program Continuation: Clear alarm with the RESET key. Restart part program
4024 Invalid axis configuration due to missing axis container machine data
Parameters: %1 = NCU number
%2 = Axis container number
Definitions: The axis configuration could not be generated due to missing axis container machine
data. This error can only occur as a result of a communication error. The communication
failure will be indicated separately by further alarms.

Other manuals for Siemens Sinumerik 840D Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Sinumerik 840D Series and is the answer not in the manual?

Siemens Sinumerik 840D Series Specifications

General IconGeneral
AxesUp to 31 axes
Power Supply24 V DC
Control TypeCNC
InterfaceEthernet, PROFIBUS
DisplayTFT color display
PLCIntegrated PLC (programmable logic controller)
Operating Temperature0°C to 45°C
Relative HumidityUp to 95% (non-condensing)
Max. Number of ChannelsUp to 10 channels