6 Manual Override
Manual Commands can be used to manually control specific points, areas,
elevators and units at your site. The following table lists the commands that can be
used to control each type and a brief description of the action that will be
performed.
The door will unlock, remain unlocked for the
defined period of time and then relock, as per a
normal valid card badge.
The door will remain blocked, unable to be opened.
Any current Permanent Command or Event Task,
or Access/Internal Action operating on the point will
be cancelled. The next Control State in the Control
State Queue will take effect.
Intrusion Control -
Disable
Disable Intrusion Control on the selected access
point.
Intrusion Control –
Enable
Enable Intrusion Control on the selected access
point.
Intrusion Control –
Restore Config
Restore Intrusion Control to whatever is configured.
The door latch will be locked until the next unlock
command is received.
The Duration can be set to:
● Until time schedule change
● Permanents
The Reader buzzer is turned off. Only applies to the
Siemens reader range.
Reader buzzer is turned on. Only applies to the
Siemens reader range.
Resets the reader tamper input. Only applies to the
Siemens reader range.
Returns the access point to the normal access
operation mode defined in the Components screen.
Restore additional
access mode
Returns the access point to the normal additional
access operation mode defined in the Components
screen.
Restore Dual
Custody Config Mode
Restores the Dual Custody mode to what is
configured.
Return to Time
Schedule Control
The door latch will return to normal Time Schedule
control.
Set “Daily Code“
additional access
mode
Set the additional access for the selected access
point to Daily Code.
Set “No Additional
Access“
Set the additional access for the selected access
point to No Additional Access.
Set “PIN as Card”
additional access
mode
Set the additional access for the selected access
point to PIN as Card.