Siemens siprotec 7sj602 User Manual

Siemens siprotec 7sj602
298 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
,QVWUXFWLRQ 0DQXDO
0XWLIXQFWLRQ 2YHUFXUUHQW DQG 0RWRU 3URWHFWLRQ 5HOD\
6,3527(& 6- 9
2UGHU 1R &* &
)LJXUH ,OOXVWUDWLRQ RI WKH PXOWLIXQFWLRQ RYHUFXUUHQW SURWHFWLRQ UHOD\ 6- LQ IOXVK PRXQWLQJ FDVH
. 6LHPHQV $*  
Question and Answer IconNeed help?

Do you have a question about the Siemens siprotec 7sj602 and is the answer not in the manual?

Siemens siprotec 7sj602 Specifications

General IconGeneral
BrandSiemens
Modelsiprotec 7sj602
CategoryRelays
LanguageEnglish

Summary

3 Technical data

3.2-3.5 Protection Functions Data

Covers data for overcurrent, earth fault, thermal overload, and breaker failure protection.

3.7-3.13 Protection Functions and Ancillary Data

Covers unbalanced load, auto-reclosure, motor monitoring, temperature, and ancillary functions.

4 Method of operation

4.1 Operation of complete unit

Describes the overall operation, hardware structure, and input processing.

4.2 Time overcurrent protection

Details the operation of time overcurrent protection stages.

4.3 Sensitive earth fault protection

Explains the operation of sensitive earth fault protection.

4.4 Thermal overload protection

Describes the operation of thermal overload protection.

4.5 Circuit breaker failure protection

Explains the operation of circuit breaker failure protection.

4.6 Unbalanced load / negative sequence protection

Details the operation of unbalanced load and negative sequence protection.

4.12 Trip circuit supervision

Details the operation of trip circuit supervision.

5 Installation instructions

5.3 Configuration of operation and memory functions

5.4 Configuration of the protective functions

Overcurrent and Earth Fault Protection Settings

Settings for phase and earth fault overcurrent protection.

6 Operating instructions

6.1 Safety precautions

Details essential safety precautions for relay operation.

6.3 Setting the functional parameters

Guides the user through setting functional parameters.

6.3.6 Settings for circuit breaker protection (address block 36)

Details settings for circuit breaker protection.

6.3.7 Settings for unbalanced load / negative sequence protection (address block 24)

Explains settings for unbalanced load and negative sequence protection.

6.3.6.2 Displacement voltage & 6.3.6.3 Direction discrimination

Configuration for displacement voltage and direction discrimination.

6.3.6.4 Direction check for earth fault protection

Explains direction checking for earth fault protection.

7 Maintenance and fault tracing