Rated Frequency | 50/60 Hz |
---|---|
Current Inputs (Number) | 3 |
Binary Inputs | 8 |
Binary Outputs | 4 |
Voltage Inputs | 3 |
Protection Functions | Overcurrent protection |
Communication Protocols | IEC 61850, Modbus |
Display | LCD Display |
Mounting Type | Panel Mounting |
Operating Temperature | -20 to +55 °C |
Storage Temperature | -40°C to +70°C |
Application | Universal protection for feeders, motors, generators, transformers, and busbars |
Describes the overcurrent protection with undervoltage seal-in logic.
Explains the directional overcurrent protection and its detection methods.
Presents setting ranges, increments, times, and tolerances for inverse-time overcurrent protection.
Provides setting ranges, increments, and tripping characteristics for thermal overload protection.
Details setting ranges, increments, trip time characteristics, and tolerances for unbalanced load protection.
Presents setting ranges, increments, times, dropout ratios, and tolerances for underexcitation protection.
Details setting ranges, increments, times, dropout ratios, and tolerances for reverse power protection.
Provides setting ranges, increments, times, dropout ratios, and tolerances for active power supervision.
Details setting ranges, increments, times, and tolerances for impedance protection.
Presents setting ranges, increments, times, dropout ratios, and tolerances for undervoltage protection.
Details setting ranges, increments, times, and tolerances for overvoltage protection.
Provides setting ranges, increments, times, dropout ratios, and tolerances for frequency protection.
Details setting ranges, increments, times, dropout ratios, and tolerances for overexcitation protection.
Presents setting ranges, increments, times, dropout ratios, and tolerances for rate-of-frequency-change protection.
Details setting ranges, increments, times, dropout ratios, and tolerances for voltage vector jump detection.
Provides setting ranges, increments, times, dropout ratios, and tolerances for 90% stator earth fault protection.
Details setting ranges, increments, times, dropout ratios, and tolerances for sensitive earth fault protection.
Presents setting ranges, increments, times, dropout ratios, and tolerances for 100% stator earth fault protection.
Details setting ranges, increments, tripping characteristics, and tolerances for motor starting time supervision.
Provides setting ranges, increments, restart threshold, and restart times for motor restart inhibit.
Details setting ranges, increments, times, and tolerances for breaker failure protection.