8 / 12 2022-06-15 M4520 74 319 0809 0 Siemens Smart Infrastructure
Indication of operating state/运行状态指示情况 SQL361B.., SQL351B..
The LED display indicating operating status can be viewed by opening the cover of the electronics module.
打开电子模块的盖子,可以通过 LED 显示看到运行状态情况。
SQL351B25..50
SQL361B25..50
Run calibration, everything ok.
1)
Automatic operation; everything ok.
1)
Internal error, troubleshooting
2)
No power
Troubleshooting, eventually replace actuator
As a general rule, the LED can assume only the states shown above (continuously red, flashing, or off).
一般来说,LED 只能呈现上述状态(持续红色、闪烁或关闭状态)。
The Green LED (D6) with short lit on when reach to “100 %” and the Red LED (D7) with short lit on when reach
to “0 %” stroke position.
When power supply to actuator but no Y control signal and also calibration not started, LED will be continuously
light too.
当到达“100 %”行程位置时,绿色 LED 灯(D6)会短暂亮起,而当到达“0 %”行程位置时,红色 LED 灯
(D7)会短暂亮起。