Installation and connection en
41
Setting hot water:
1. Open the door.
2. Switch on ON/OFF switch (.
3. Hold down programme button #
and press START button `
until •:‹... is indicated on the digital
display.
4. Release both buttons.
The LED for button # flashes and
the digital display h displays the
factory setting •:‹….
5. Press programme button # until
the factory set value ‘:‹‹
is indicated on the digital
display h.
To change the setting:
1. By pressing the 3 button, you can
switch the hot water setting off ‘:‹‹
or on ‘:‹‚.
2. Press START button `.
The set value is saved.
3. Close the door.
Electrical connection
ヽ Connect the appliance to an
alternating current only, ranging from
220 V to 240 V and 50 Hz or 60 Hz
via a correctly installed socket with
protective earth conductor. See
rating plate for required fusing 9J.
ヽ The socket must be near
the appliance and freely accessible
following installation.
If the plug is not freely accessible, an
allpole disconnector with a contact
opening of at least 3 mm must be
fitted on the installation side
to satisfy the relevant safety
instructions.
ヽ The connection may be modified by
technicians only.
ヽ A power cord extension may be
purchased from customer service
only.
ヽ Use only a residual current operated
circuit-breaker which features
the symbol ‚. Only this extension
guarantees compliance with
the currently valid regulations.
ヽ The appliance features a water
damage protection system. Please
note the system will not function
unless the power supply
is connected.