WL Circuit Breaker
1/19
WL Selection and Application Guide • 2005
Components and Accessories
Locking Devices Mounted on the Guide Frame
Lock Breaker in OPEN position, KIRK Key WLDLKRK 750
Lock Breaker in OPEN position, Superior Lock WLDLSUP 675
Double Lock Breaker in OPEN position, KIRK Key WLDLDKRK 1,450
Double Lock Breaker in OPEN position, Superior Lock WLDLDSUP 1,305
Provision Only - Lock Breaker in OPEN position WLDLPR 247
Provision Only - Double Lock Breaker in OPEN position WLDLDPR 350
Locking Device
against opening the cubicle door if breaker is in connect position, WLDRLC1 180
FSII & FSIII
Locking Device against opening the cubicle door if breaker is in connect position, FSI WLDRLC 180
Locking Device
against closing the breaker if the cubicle door is open WLDRLC5UL 237
and breaker is in the connect position (UL 489 only)
Circuit Breaker / Non-Automatic Switch Guide Frames and Accessories
3-Phase Metering CTs, Guide Frame mounted (3 windows per CT)
Rating
Frame Size I & II 100:5 WLG1005MCT2 1,158
150:5 WLG1505MCT2 1,158
200:5 WLG2005MCT2 1,158
250:5 WLG2505MCT2 1,158
300:5 WLG3005MCT2 1,158
400:5 WLG4005MCT2 1,158
500:5 WLG5005MCT2 1,158
600:5 WLG6005MCT2 1,158
800:5 WLG8005MCT2 1,158
1000:5 WLG10005MCT2 1,158
1200:5 WLG12005MCT2 1,158
1500:5 WLG15005MCT2 1,158
1600:5 WLG16005MCT2 1,158
2000:5 WLG20005MCT2 1,158
2500:5 WLG25005MCT2 1,158
3000:5 WLG30005MCT2 1,158
3200:5 WLG32005MCT2 1,158
Frame Size III 2000:5 WLG20005MCT3 1,623
2500:5 WLG25005MCT3 1,623
3000:5 WLG30005MCT3 1,623
3200:5 WLG32005MCT3 1,623
4000:5 WLG40005MCT3 1,623
5000:5 WLG50005MCT3 1,623
GZ
GZ
GZ
GZ
GZ
GZ
GZ
GZ
GZ
GZ
GZ
GZ
GZ
GZ
GZ
GZ
GZ
GZ
GZ
GZ
GZ
GZ
GZ
Guide Frame Accessories
Description Catalog Number List Price $
Shutter
Field installable and lockable with Frame Size I UL 489 S, H, L-Class WLGSHUT1UL 450
padlock provision Frame Size II ANSI / UL 489 N, S, L, F-Class WLGSHUT2 515
UL 489 C-Class WLGSHUTM2 515
Frame Size III ANSI / UL 489 H, L, F-Class WLGSHUT3 575
Frame Size III ANSI / UL 489 M, C-Class WLGSHUTM3 575
Guide Frame Arc Chute Cover Frame Size I UL 489 S, H, L-Class WLGARC1UL 295
Frame Size II ANSI N, S, H, L-Class WLGARC2 337
UL 489 S, L-Class WLGARC2UL 337
ANSI / UL 489 H, L-Class WLGARC3 425
Mechanism Operated Auxiliary Contacts (MOC)
Mounted on the Guide Frame (drawout breakers only)
4NO+4NC, Test and Connect position FSI & FSII WLMOC 800
4NO+4NC, Connect position only FSI & FSII WLMOCC 700
4NO+4NC, Test and Connect position FSIII WLMOC3 800
4NO+4NC, Connect position only FSIII WLMOCC3 700
For fixed mount breakers
4NO+4NC FSI WLMOCUL1 700
4NO+4NC FSII WLMOCUL 700
Guide Frame Heater WLGHEAT 62
NSE01008
WLGARC2
GZ
WLEF2
Coding Kit for Drawout Breakers
Breaker Coding Kit for different breaker styles Frame Size I (UL 489 only) WLBCK1
120
Frame Size II WLBCK2
120
Frame Size III WLBCK3
120
Additional Grounding Between Breaker and Guide Frame
Additional ground protection for the Guide Frame Frame Size II WLEF2 86
Frame Size III WLEF3 86
NSE01009
WLBCK2
1
Breakers are coded for frame rating and interrupting
capacity standard from the factory.
1
WLGSHUT2
Guide Frame Z-Parameter accessory. This component can
be added to an assembled guide frame catalog number order.
GZ