PSA / PVA Installation Guide
April 20, 2023 Sifos Technologies Page 24
Slot,Port Type Version
--------- --------------------- -------
0,0 PSA3000_Controller_01 3.13
1,1 PSA3202_Test_Blade_08 4.14
1,2 PSA3202_Test_Blade_08 4.14
2,1 PSA3202_Test_Blade_08 4.14
2,2 PSA3202_Test_Blade_08 4.14
3,1 PSA3202_Test_Blade_08 4.14
3,2 PSA3202_Test_Blade_08 4.14
4,1 PSA3102_Test_Blade_08 3.2a
4,2 PSA3102_Test_Blade_08 3.2a
5,1 PSA3102_Test_Blade_05 3.2a
5,2 PSA3102_Test_Blade_05 3.2a
6,1 PSA3102_Test_Blade_03 3.2a
6,2 PSA3102_Test_Blade_03 3.2a
While the update is running to each test port, the LED’s on that test port being upgraded will flash. When the
upgrade process has completed, PowerShell will indicate that the download is complete, and will return to a standard
prompt.
NOTE! This firmware upgrade will take minutes per Test Port. Do NOT interfere with the operation of PowerShell
or the PSA-1200 Chassis during this period of time. Do NOT cycle power to the PSA-1200 Chassis.
The following example upgrades a hardware version 6 PSA-3102 test port in slot 3, port 1:
PSA-4,1>psa_update_fw 3,1 file c:/psx-3102v032a_hw1-6.hex
PSA_CHASSIS_ADDRESS: 192.168.221.105. Confirm download file /psa firmware/pseat-2/psx-
3102v0316.hex
to PSA? (YES | NO)
YES
Transferring file c:/psx-3102v0320_hw1-6.hex of size 219834 bytes to 192.168.221.105...
File contains 1173 64 byte blocks
writing block 1 of 1173
writing block 2 of 1173
writing block 3 of 1173
writing block 4 of 1173
writing block 5 of 1173
writing block 6 of 1173
writing block 7 of 1173
writing block 8 of 1173
writing block 9 of 1173
...
writing block 1173 of 1173
File Transfer completed in 570 seconds.
DOWNLOAD COMPLETE. PLEASE RE-CYCLE POWER TO THE PSA1200 AT 192.168.221.105.
NOTE! If you are upgrading the firmware of multiple Test Ports, you can wait to “RE-CYCLE POWER” until after
all the Test Ports have been upgraded.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sifos Technologies PSA-3000 and is the answer not in the manual?

Sifos Technologies PSA-3000 Specifications

General IconGeneral
BrandSifos Technologies
ModelPSA-3000
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals