5-SDG2000X Quick Start
7.Channel Control Area
CH1 Control/Output Key
The Output key on the left is used to turn on/off CH1 output.
The nominal output impedance of the BNC connector is 50Ω.
When pressing Output (the key backlight turns on), the connector outputs waveform according to the current conguration of CH1.
CH2 Control/Output Key
The Output key on the right is used to turn on/off CH2 output.
The nominal output impedance of the BNC connector is 50Ω.
When pressing Output (the key backlight turns on), the connector outputs waveform according to the current conguration of CH2.
8.Channel Select Key
This key is used to switch the current selected channel between CH1 and CH2.
CAUTION:
Overvolltage protection of CH1 and CH2 will take effect once any of the following conditions is met. When overvoltage protection occurs, a message will
be displayed and the output is disabled.
The absolute value of input voltage is higher than 11V±0.5V when the amplitude of the generator is higher than or equal to 3.2Vpp or the DC offset is
higher than or equal to |2VDC|.
The absolute value of input voltage is higher than 4V±0.5V when the amplitude of the generator is lower than 3.2Vpp or the DC offset is lower than
|2VDC|.
Choose Utility
Page 1/2
OverVoltage Protection to turn on/off the function.

Other manuals for SIGLENT SDG2122X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SIGLENT SDG2122X and is the answer not in the manual?

SIGLENT SDG2122X Specifications

General IconGeneral
BrandSIGLENT
ModelSDG2122X
CategoryInverter
LanguageEnglish

Related product manuals