Page #14 background imageLoading...
Page #14 background image
SDG2000X_ServiceManual_SM
0202X-E01B.doc
14
Square Characteristics
Duty cycle
0.001
99.999
%
Limited by frequency setting
Jitter (rms),
Cycle to cycle
150
ps
1 Vpp, 50 Ω Load
Pulse Characteristics
Parameter
Min.
Typ.
Max.
Unit
Condition
Frequency
25M
Hz
Pulse width
16.3
ns
Pulse width
accuracy
±(0.01%+0.3ns)
Rise/fall times
8.4n
22.4
s
10% ~ 90%, 1 Vpp, 50 Ω Load,
Subject to pulse width limits
Overshoot
3
%
100 kHz, 1 Vpp
Duty cycle
0.001
99.999
%
Limited by frequency setting
Duty cycle
resolution
0.001
%
Jitter (rms)
cycle to cycle
150
ps
1 Vpp, 50 Ω Load
Ramp Characteristics
Parameter
Min.
Typ.
Max.
Unit
Condition
Frequency
1M
Hz
Symmetry
0
100
%
Linearity
1
%
Percentage of peak-peak output,
1 kHz, 1 Vpp, 100% symmetry
Noise Characteristics
Parameter
Min.
Typ.
Max.
Unit
Condition
-3dB
bandwidth
120
MHz
Arbitrary Wave Characteristics
Parameter
Min.
Typ.
Max.
Unit
Condition
Frequency
20M
Hz
Waveform
length
8
8M
pts
Sampling rate
75M
Sa/s
TrueArb mode
300
MSa/s
DDS mode
Vertical
solution
16
bit
Jitter (rms)
150
ps
1 Vpp, 50 Ω Load, TrueArb mode

Other manuals for SIGLENT UM0202X-E02C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SIGLENT UM0202X-E02C and is the answer not in the manual?

SIGLENT UM0202X-E02C Specifications

General IconGeneral
BrandSIGLENT
ModelUM0202X-E02C
CategoryInverter
LanguageEnglish

Related product manuals