C-DIAS IPC WITH AMD FUSION G-T56N C-IPC 171
04.11.2019 Page 35
The operating system is currently being
reprogrammed.
The operating system has been rein-
stalled.
The operating system cannot be loaded;
too little memory.
Restart; report error to SIGMATEK.
Boot loader message.
No operating system found in RAM.
Restart; report error to SIGMATEK.
The boot loader is searching for the
operating system in RAM.
Restart; report error to SIGMATEK.
The operating system loaded does not
match the hardware configuration.
Solution:
- Use the correct operating system
version
The LASAL Module or project cannot be
loaded.
Solution:
- Recompile and download the
entire project
A general error has occurred while
loading the operating system.
An error has occurred in the application
memory (user heap).
Solution:
- Correct allocated memory access
error
This error does not occur in the control.
This error code is used in the
programming system to show that
there is no connection to the
control.
An error number was entered in the
VARAN manager and stopped the
program.
Solution:
- Read log file
A required VARAN client was discon-
nected or communication error has
occurred.
Solution:
- Read LogFile
- Error Tree
An error has occurred while loading the
application.
Cause:
- Application was deleted.
Solution: