36
TROUBLESHOOTING, Continued
#6 SYMPTOM: LOWER STRAP SLIPPING THROUGH SEAL AND SEAL BUCKLES
CAUSE REMEDY
1. Improper seals being used.
2. Incorrect tool operating pressure or
tension regulator set too high.
1. Check that the proper Signode seals
are being used (See page 4 of this
manual).
2. Decrease tension by adjusting
regulator on the air motor.
#7 SYMPTOM: SEAL SLIPPING INTO THE NOSE OF TOOL.
CAUSE REMEDY
1. Improper seals being used.
2. Worn tensioner foot.
1. Check that the proper Signode seals
are being used (See page 4 of this
manual).
2. Check slot in tensioner foot (83). Slot
width should be .045" to .053"
(1.15mm - 1.35mm). If opening
exceeds this, check and replace if
necessary.