Marker 2000
F.A.Q.
www.silca.biz
Testing of motors, sensors, magnet, laser (red box), temperature and etc.
A. (F4) diagnosis.
B. Then choose what level of testing you want to go in.
C. Press (esc) to escape.
Calibrating sensors (2).
A. (F5) set up.
B. (F10) to go on.
C. Press (F10), at this point it shows quantity of pieces made, serial number, keyboard.
D. Press (F8), put in small black key template with small boxes on the jaw with clamp.
E. Press (F10) and centre punch on the template hole and push down on punch (manually).
F. Press (F10) and bring the sensors to the closest point to on/off position, but stay off X and y axis (x) first.
G. Press (F10) to go on.
H. Use arrows on keyboard to regulate laser (red boxes) on template, do 1-8 to move on and then press
(F10) to continue 8-16.
I. Press (F10) to save regulation of boxes.
J. When finished with slides, press (esc) to go back to the main menu.