SE430 3 revised 10/15/15
SE430 Mini DA Sander
OPERATION
Always turn off the air supply, drain hose of air pressure and detach
tool from air supply before installing, removing or adjusting any part or
accessory on this tool, or before performing any maintenance on this
tool.
Aftermountingsandpaper,startthissanderunderabenchinorderto
make sure sandpaper is firmly attached. Set the sander down on the
work evenly and move it slowly back and forth in wide, overlapping
areas.Additionalpressuremaybeusedtomakemoreefficientuseofthe
tool when material to be sanded is thick. Lighter pressure may be used
in delicate sanding or when using edges of sanding pad. Whenfinished
sanding, lift it off the work before stopping the motor.
NOTE: During operation, safety goggles should always be worn to
guard against flying rust and chips (users and bystanders).
AIR SUPPLY
Tools operate on a wide range of air pressures. It is recommended that
air pressure measures 90 psig at the tool with the trigger fully depressed
andnoloadappliedtothetool.Higherpressure(over90psig;6.2bar)
raises performance beyond the rated capacity of the tool, which will
shortentoollifeandcouldcauseinjury.
Alwaysuseclean,dryair.Dust,corrosivefumesand/orwaterintheair
line will cause damage to the tool. Drain the water from air lines and
compressorpriortorunningtool.Cleantheairinletfilterscreenweekly.
TherecommendedhookupprocedurecanbeviewedinFIG.1.
Theairinletusedforconnectingairsupplyhasstandard1/4"NPT.Line
pressure should be increased to compensate for unusually long air
hoses (over 25 feet). Minimum hose diameter should be 3/8" I.D. and
fittings should have the same inside dimensions and be tightly secured.
Ensure an accessible emergency shut off valve has been installed in the
air supply line and make others aware of its location.
LUBRICATION AND MAINTENANCE
Lubricate the air motor daily with high quality air tool oil. If no air line oiler
isused,run1/2oz.ofoilthroughthetool.Theoilcanbesquirtedintothe
tool air inlet or into the hose at the nearest connection to the air supply,
thenrunthetool.Arustinhibitiveoilisacceptableforairtools.
WARNING:Afteranairtoolhasbeenlubricated,oilwilldischargethrough
theexhaustportduringthefirstfewsecondsofoperation.Theexhaust
port must be covered with a towel before applying air pressure to prevent
seriousinjury.
TROUBLESHOOTING
Other factors outside the tool may cause loss of power or erratic action.
Reducedcompressor output,excessive drain onthe airline, moisture
or restrictions in air pipes or the use of hose connections of improper
size or poor condition may reduce air supply. Grit or gum deposits in the
tool may cut power and may be corrected by cleaning the air strainer
and flushing out the tool with gum solvent oil or an equal mixture of
SAE#10oilandkerosene.Ifoutsideconditionsareinorder,andthetool
continues erratic action or low power, disconnect tool from hose and
contact your nearest authorized service center.
WARRANTY
SilverEagle
®
byMatcowarrantsitsairtoolsforaperiodof1yearto
theconsumer.WewillrepairanySESeriesairtoolcoveredunderthis
warranty which proves to be defective in material or workmanship during
the warranty period. In order to have your tool repaired, return the tool
toanySilverEagleAuthorizedWarrantyCenter,freightprepaid.Please
include a copy of your proof of purchase and a brief description of the
problem. The tool will be inspected and if any part or parts are found to
be defective in material or workmanship, the tool will be repaired free of
charge and returned to you freight prepaid.
This warranty gives you specific rights. You may also have other rights
which vary from state to state.
The foregoing obligation is Matco’s sole liability under this or any implied
warranty and under no circumstances shall Matco be liable for any
incidental or consequential damages.
Note: Somestatesdonotallowtheexclusionorlimitationofincidental
orconsequentialdamagessotheabovelimitationorexclusionmaynot
apply to you.
FIG. 1
Drain Daily
RegulatorOilerQuick CouplerLeader
Hose
Nipple
Do Not Install
Quick Coupling
Here
Nipple
Filter
Air Supply
Whip Hose
Air Inlet
Trigger