When refuelling at a service station, do not use a plastic funnel, since it will prevent the
tension between the refuelling nozzle and filling vent from being discharged.
Hint: If you are afraid of getting fuel on the synthetic teak deck during refuelling, wet the
deck with water. You can also hold a rag in front of the fuel filler to prevent fuel from
splashing on the deck.
Always keep a spare can of fuel on board. The anchor boxes at the stern are especially
suitable for storing the spare canister as there is no risk of vaporised fuel coming into
contact with battery compartments or the electrical system from either of these boxes.
Do not stow any loose items under the aft sofa that could prevent fuel flow to the engine if
they shift. Check the fuel hoses annually for wear, especially at through fittings.
Please note that, depending on the trim of the boat or the boat's heeling angle, it might not
be possible to use the full capacity of the fuel tank.
If the boat is on trailer behind a car when refuelling, please note that the fuel tank
ventilation does not work efficiently if the bow of the boat is downwards.
WARNING! Vaporised fuel is highly explosive. Observe these instructions and the utmost
caution during refuelling. The smell of fuel always means that there is
vaporised fuel on your boat.
5.7.2 Other fuel-operated systems (diesel heater optional accessory)
The diesel-operated heater (optional accessory) has its own user manual and the operation
is not described in this manual. The fuel tank for the heater is located underneath the aft
sofa. Turn off the heater when refuelling the diesel tank. When handling diesel, do not use
switches or appliances that can cause a spark. Always clean any spilled fuel immediately.
NOTE! If the boat is equipped with a heater (optional accessory), do not
block the exhaust grates when the heater is switched on. This will
cause the heater to overheat and engage the overheat protector.
5.7.3 Fire protection
The boat is equipped with a portable 2 kg fire extinguisher class 8A 68 B, which is the
minimum power requirement for extinguishers. For the extinguisher to remain reliable, it
should be inspected annually by an authorised inspector. In the event that the fire
extinguisher is replaced, the capacity of the new one must be at least equivalent to the old.
The fire extinguisher in the storage compartment behind the driver.