EasyManua.ls Logo

Silvercrest SKWH 2000 A2 - Page 18

Silvercrest SKWH 2000 A2
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GB/IE/NI/CY/MT16
The distance to the floor must be at least 2m
(see figure 7 and 8).
If the predefined distances cannot be com-
plied with, the device should not be mounted.
The ceramic wall fan heater should only
be used in the protection area 3 of a
bathroom (see figure 8)!
8
Protection zones
Protection area 0 Protection area 1 Protection area 2 Protection area 3
Protection area 1
Protection area 0
Protection area 2
**Protection area 3
60cm
225cm
45cm
200cm
60cm
225cm
Protection area 0 This is the area that is inside
the bathtub or shower tray.
Protection area 1 This area is limited in height
(225 cm) and extends to the
outer edges of the bathtub
or shower tray.
Protection area 2 This area is limited in height
(225 cm) and extends to the
vertical surfaces at the limit
of zone 1 and its parallel
vertical surfaces extending
60 cm beyond the edge of
zone 1.
Protection area 3 Protection area 3 applies
to areas outside the three
protection areas mentioned
above.
7

Table of Contents

Related product manuals