Loading...
scorpION3 5200969 Rev 4 28
During normal operation, the Positive Ion and Negative Ion
indicators on the scorpION3 face label will glow green. If the bar is
in the steady state mode, the indicators will glow continuously. If the
bar is in the pulse mode, the indicators will flash alternately (with
both on during overlap), indicating ion output. If a fault occurs, the
indicator color will change to red. The indicators will typically briefly
flicker to show the receipt of IR commands from the MMI.
The scorpION3 bar with Air Assist provides reduced discharge
times according to the following table:
Table 4. scorpION3 with Air Assist: Typical Discharge Time Reduction
The typical recommended operating pressure for the scorpION3
with Air Assist is 200 kPa (30 psi). Pressures less than 50 kPa (7.5
psi) may provide an air purge, but provide little overall reduction in
discharge times. Pressures greater than 300 kPa (45 psi) increase
air consumption without providing significant gains in discharge
time reduction. Compressed air or nitrogen must be clean, dry and
oil free.
Operating Pressure
50 kPa
(7.5 psi)
100 kPa
(15 psi)
200 kPa
(30 psi)
300 kPa
(45 psi)
400 kPa
(60 psi)
Typical Discharge Time
Reduction
10% 30% 50% 60% 65%