scorpION3 5200969 Rev 4 3
A scorpION3 bar may be designated as a master; it will then talk to
the other bars connected to it via integrated RS-485
communication. The master maintains contact with each bar to
synchronize system operations. Individual bars connected in a
system monitor and store their own operating parameters. If a
problem should occur, each bar has the capability to visually
indicate a fault condition and also provide an output that can be
integrated into system control hardware.
Adjustment of ion output and balance can be made to individual
scorpION3 bars via the hand-held MMI module (Man Machine
Interface) which features two-way communication with the bars via
wireless infrared or hardwired RS-485 on a modular cable.
Individual bar addressing ensures adjustment of only the desired
bar. Operating mode and pulse frequency are adjusted at the
individual bar or the master bar depending upon configuration.
The scorpION3 CI (Computer Interface) provides an interface
between the scorpION3 bar system and a personal computer or
local computer network. With Simco-Ion’s interface software, a
user may set-up, monitor or control the scorpION3 bar system from
their computer. The scorpION3 CI provides for communication via
an Ethernet connection.