List of parameters refer to table below:
Parameter No
Description
Range
Remark
F0
Discharge temperature
0~130
Display "--" when faulty
F1
Ambient temperature
-30~100
Display "--" when faulty
F2
Evaporator coil temperature
-30~100
Display "--" when faulty
F3
Suction temperature
-30~100
Display "--" when faulty
F4
Open pulse of EEV
F5
Controller version No.
F6
PCB version No.
F7
Solar collector temperature
0~150
Display "--" when faulty
2. Configuring parameters
From home page, press and button at the same time for 3s to enter into parameter
configuring page.
Temperature area display parameter code, clock area display value.
Press or button and adjust the data of special parameters.
Press button for confirmation or scroll to next parameter.
Press button or button or without any operation within 30 seconds, the system will
return to the home page.
List of parameters can be configured refer to table below:
Parameter No
Description
Range
Default
S0
Defrost exit temperature
5~30
20
S1
Defrost cycle
10~90 minutes
45
S2
Defrost operation time
5~18 minutes
10
S3
Correction for tank water temperature
-5~5
0
S4
Tank water temperature differential
2~12
5
S5
Defrost enter temperature
-10~5
-10
S6
Status of anti-freeze
0-deactivate,1-activate
1
S7
Status of anti-legionella
0-deactivate,1-activate
0
S8
Status of Photovoltaic
0-deactivate,1-activate
0
S9
Tset for timer 1
40~75
50
SA
Tset for timer 2
40~75
65
Sb
Tset for timer 3
40~75
65
Sc
Status of solar pump
0-deactivate,1-activate
0
SE
Status of E-Anode
0-deactivate,1-activate
1
SF
Status of Wi-Fi
0-deactivate,1-activate
1