19
DESCRIPTION
Edea
30 40
CERTIFICATIONS
Country of intended installation GB
Fuel G20 - G31
PIN number 1312CU6393
Category II2H3P
Appliance classification B23P - B33P - B53P - C13 - C33 - C43 - C53 - C63 - C83 - C93 - C(10)3
DHW rated useful heat output kW 30,0 40,0
Class NO
x (*) 6 (< 56 mg/kWh)
HEATING PERFORMANCE
HEAT INPUT (**)
Nominal flow (Q
n max) kW 25 34,8
Minimum flow G20/G31 (Q
n min) kW 3,0 / 4,0 4,5 / 5,5
HEAT OUTPUT
Nominal (80-60°C) (P
n max) kW 24,5 34,1
Nominal (50-30°C) (P
n max) kW 26,4 36,7
Minimum G20 (80-60°C) (P
n min) kW 2,8 4,2
Minimum G20 (50-30°C) (P
n min) kW 3,1 4,7
Minimum G31 (80-60°C) (P
n min) kW 3,7 5,1
Minimum G31 (50-30°C) (P
n min) kW 4,2 5,7
EFFICIENCY
Max useful efficiency (80-60°C) % 98 98
Min useful efficiency (80-60°C) % 93,3 93,3
Max useful efficiency (50-30°C) % 105,8 105,6
Min useful efficiency (50-30°C) % 104,7 104,2
Useful efficiency at 30% of load (40-30°C) % 108,7 108,5
Losses after shutdown at 50°C W 105 115
DOMESTIC HOT WATER PERFORMANCE
Nominal heat input (Q
nw max) kW 30 40
Minimum heat input G20/G31 (Q
nw min) kW 3,0 / 4,0 4,5 / 5,5
Specific D.H.W. flow rate ∆T 30°C (EN 13203) l/min 13,0 18,8
Continuous D.H.W. flow rate (∆T 25°C / ∆T 35°C) l/min 16,9 / 12,0 22.5 / 16.1
Minimum D.H.W. flow rate l/min 2,0 2,0
Max (PMW) / Min Pressure
bar 7 / 0,5
kPa 700 / 50
ENERGY PERFORMANCE
HEATING
Heating seasonal energy efficiency class A A
Heating seasonal energy efficiency % 93 93
Sound power dB(A) 55 56
DOMESTIC HOT WATER
Domestic hot water energy efficiency class A A
Domestic hot water energy efficiency % 86 86
Stated domestic hot water profile load XL XXL
ELECTRICAL SPECIFICATIONS
Power supply voltage V 230
Frequency Hz 50
Absorbed electrical power (Q
n max) W 93 113
Absorbed electrical power at (Q
n min) W 67 65
Absorbed electrical power in stand-by W 4 6
Electrical protection degree IP X5D
COMBUSTION DATA
Smoke temperature at Max/Min flow (80-60°C) °C 80,0 / 62,0 74,5 / 58,2
Smoke temperature at Max/Min flow (50-30°C) °C 51,3 / 42,5 52,3 / 44,2
Smoke flow Max/Min g/s 14,5 / 1,5 18,8 / 2,2
CO
2 at Max/Min flow rate (G20) % 9,2 / 9,0 9,3 / 9,1
CO
2 at Max/Min flow rate (G31) % 10,2 / 10,0 10,0 / 10,0
NOx measured mg/kWh 15 34
Gas consumption at Max/Min flow rate (G20) m
3
/h 3,17 / 0,32 4,23 / 0,48
Gas consumption at Max/Min flow rate (G31) kg/h 2,33 / 0,31 3,11 / 0,43
Gas supply pressure (G20/G31)
mbar 20 / 37 20 / 37
kPa 2 / 3,7 2 / 3,7