40
EN
System inertia
This is a parameter which adjusts the reaction time of the ad-
justment algorithm, to be associated with inertia or with the
size and type of building and the heating system.
Flow Temp. min. set
It is the lower limit of the calculated flow temperature (use-
ful in the case of low efficiency systems with low calculated
temperatures)
Antifreeze enable
YES setting
: enable the antifreeze protection program
NO setting: the heating will remain off when in the function
mode OFF, SUMMER and in periods of Reduced mode AUTO if
the room sensor is disabled.
Antifreeze set
This is the room temperature (antifreeze) below which the de-
vice makes a heating request at the minimum flow set. The
request remains active until the room temperature has ex-
ceeded the "antifreeze temperature + 0.6°C”
Room probe offset
This is the value used to correct the room temperature read-
ing by the sensor inside the device.
4.3 Settings from the MODE button
From the
“main screen”
Th 20 Mar 2014Zone 1 10:30
Winter manual - set 20.0°C
Menu Mode
Press the button
Mode
to go into the screen to select
“Function mode”
One of the three Modes will be highlighted
(eg. “Winter”)
Esc Back
Winter
Off
Summer
Press the encoder
clic
k
to confirm the highlighted
“Mode”
and go into the
“rows”
Esc Back
Winter
Hot water MAN 40°C
Heating MAN 20.0°C
Holiday function OFF
Rotate the encoder to select
“Heating”