Page #18 background imageLoading...
Page #18 background image
17
5.
Use function mode
In standby mode (ie, no water status), press the function (@) key, you can select "Auto", "Eco",
"normal" three modes in turns, they can cycle, the system default normal mode.
Three types of function mode instruction
Normal mode (default): According to the user to set automatic temperature thermostat, then
"Auto", "Eco" display lights are not bright.
Auto mode: ("Auto" display lights is bright.) According to the inlet water temperature, the
system automatically adjusts the setting temperature (as shown in Table 1), allowing users to get
the most comfortable hot water supply in anytime.
Table 1 Temperature mapping table
No.
Local Water Temperature
Corresponding Temperature
1
≤ 15
o
C
45
o
C
2
16
o
C‐21
o
C 43
o
C
3
22
o
C‐27
o
C 40
o
C
4
≥ 28
o
C
38
o
C
Note: Under the Auto mode, after the heater switch‐on, the temperature displayed is the one set
before the heater starts to work. The temperature will not change according to the local water
temperature change after the heater starts to work.
Eco mode: ("Eco" display lights is bright.) In the state of saving mode, after calculation by
microcomputer, automatically adjust the amount of gas supply, compared other modes more
economical by water heater gas consumption, not only save gas, but also can guarantee a
constant water temperature to meet the requirements of users.
In the state of saving mode, the user can freely select the desired of setting water temperature,
the user presses the up or down keys to adjust the setting temperature does not exit the power
saving mode, in this case the user needs in the standby mode press the function key again to exit
the power‐saving mode.
6.
Instant hot water production and real‐time air consumption display
When the water heater in working condition, the display will take turns showing the current real‐
time hot water production and real‐time gas consumption, the figures will be changed accord the
actual working conditions, so that users can understand the water heater current working
conditions.
For example: When the real‐time information display "12.0 L / min", indicates that current real‐
time hot water production by water heater per minute 12 L. When the real‐time information
display "2.0m³/h", indicates that current real‐time gas consumption by water heater per hour
2.0m³
Fig. 13