24
Enclose: Explanation of the Error Codes
In the process of using, the display of the fire, wind and other patterns disappeared, because the
security device has been caused by action. Display flashing fault code shows that the failure of its
occurrence, the reason for the exception.
Fault code has been flashing when failure. On such occasions, please turn off the hot water value
and then open, or close / open the monitor, and then operate 1‐2 times. If the display still show
the fault code, please be sure to close the water valve and valve, unplug the power plug, and
contact the after‐sales service.
Error Code
Explanation
01
Inlet water temperature sensor breaks down
10
Detect a flame signal through pre‐check
11
Ignition fails
12
Normal combustion flames out accidentally
13
Thermostat fault protection
30
Block due to obstruction of the smoke exhaust
32
Fan blocking protection
40
Fan or its drive circuit breaks down
50
Over high temperature protection
outlet > 80°C
51
Over high temperature protection
inlet > 65°C
60
Outlet water temperature sensor fault protection
70 Incorrect setting of the values for water quantity, type
of gas and model
Packaging and Accessories
Description
Quantity
Gas water heater
1
Connector of gas inlet (with rubber seal ring)
1
Expansion screws
1
Mounting screws
2
User manual
1
Self‐tapping screws
2
Flue duct
B
23
type
1