CLEANING (Fig. 60)3.3.5
Cleaning operations must be carried out at
regular intervals and only when the boiler
is cold.
Combustion products collect in the remov-
able drawer that must be emptied before
starting the boiler. To remove all combus-
tion residuals, use a brush and vacuum and
verify that all the ashes inside the combustion
chamber have been completely removed.
The vacuum can also be used to clean the
pellet grille.
To clean the fume ducts inside the boiler
body, use a brush.
ATTENTION: if the generator is switched
off for long periods of time (above 15
days), it is necessary to empty the 80 kg
pellet container in order to prevent the
pellets from absorbing excessive humid-
ity, which could affect the operation of
the boiler. A high amount of humidity in
the pellets could cause them to pulverize,
increase the amount of ash in the brazier
and obstruct the pellet feeding system.
ANNUAL MAINTENANCE3.3.6
For optimum performance, it is advisable
to have the boiler serviced regularly and
thoroughly by qualified personnel at least
once every year.
Before performing maintenance opera-
tions, verify that the boiler is cold and has
been disconnected from the mains.
Fig. 60
Removable
drawer
Pellet grille
ACCESSORIES3.3.7
ACCESSORY KIT:
- 5197500 200-litre PELLET TANK
- 5197510 300-litre PELLET TANK