Problem Look for Remedy
Unit fails to discharge snow. Auger drive belt loose or damaged. See authorized dealer.
Auger control cable not adjusted cor-
rectly.
Adjust auger control cable. Refer to
Maintenance section of this manual.
Broken shear pin or shear bolt. Replace shear pin or bolt. Refer to
Maintenance section of this manual, or
see an authorized dealer.
Discharge chute clogged. Stop engine immediately. Always use
the clean-out tool to clear a clogged
discharge chute, not your hands. Clean
discharge chute and inside of auger
housing. Refer to Discharge Chute
Warning in the Operator Safety section.
Foreign object lodged in auger. Stop engine immediately. Always use
the clean-out tool to clear a clogged
chute, not your hands. Remove object
from auger. Refer to WARNINGS in the
Operator Safety section.