PREPARING AND INSTALLING THE FUEL CELL (GFC34)
GENERAL OPERATING INSTRUCTIONS FOR THE
GCN150/GCN-MEP GAS-ACTUATED TOOL
1. Remove safety cap from metering valve.
2. Insert front legs of metering valve inside
top shoulder of fuel cell.
3. Push the back legs inside top shoulder of
fuel cell until it snaps into place.
4. Place fuel cell into fuel compartment with
meter valve end in the upward position.
5. Push the metering valve stem into the red
triangle carburetor.