DC Inverter UNI SPLIT Series
Duct
Type Unit
37
④.
The external power cord, connection wire of indoor and outdoor units and the
communication cords must be effectively fixed.
⑤.
The external power cord, connection wire of indoor and outdoor units and the
communication cords can’t directly
contact any hot objects.
For example: they
must not contact chimney pipes, warm gas pipes or other hot objects.
⑥.
The
external
power
cord,
communication
cords,
and
the
connection
wire
of
indoor and outdoor units must not be squeezed.
Never pull, stretch or
bend the
wires.
⑦.
The
external
power
cord,
communication
cords
and
the
connection
wire
of
indoor and outdoor units must not
collide
with any metal beam or edge on the
ceiling, or touch any metal burrs or sharp metal edge around.
⑧.
Connect
wires correspondingly by referring
to the circuit diagram
labeled
on
the unit or electric box. Screws must be tightened up.
Slipped
screws must be
replaced by
specialized
flat-head screws.
⑨.
Please use the power cables that are delivered along with the air conditioner.
Do
not
change
the
power
cables
arbitrarily.
Do
not
change
the
length
and
terminals of the power cables.
If you want to change the power cables, please
contact Sinclair’s local service center.
⑩.
Wiring
terminals
should
be
connected
firmly
to
the
terminal
board.
Loose
connection is forbidden.
⑪.
After the electrical installation is finished, please use wire clamps to secure the
power
cord,
connection
wire
of
indoor
and
outdoor
units
and
the
communication cords.
Make sure the wires are not clamped too tight.
⑫.
The wire gauge
of power cord should be large enough.
Damaged power cord
or
other
wires
must
be
replaced
by
specialized
wires.
Wiring
work
must
be
done according to national wiring rules and regulations.