DC INVERTER U-MATCH AIR CONDITION MAINTENANCE
181
Removal of Water Tray
Remark: Before removal, please make sure that the power supply has been cut off. During removal, please
protect the parts properly.
Step Illustration Handling Instruction
1. Remove the
cover board
Loosen the screws fixing
the lower cover board and
remove the lower cover
board. (As shown, what
the circle indicates are 6
screws fixing the lower
cover board and what the
square indicates are 2
screws on left and right
respectively fixing the
water tray).
2. Remove the
water tray
Remove the screws
fixing the water tray and
pull upward to remove the
water tray. The water tray
after removal is as shown
on left.
Removal of Fan and Motor
Remark: Before removal, please make sure that the power supply has been cut off. During removal, please
protect the parts properly.
Step Illustration Handling Instruction
1. Remove the
fan
Remove the screws
fixing the fan
sub-assembly. (There
are 6 screws, as
shown by the circle in
Fig. 10)