DC INVERTER U-MATCH AIR CONDITION MAINTENANCE
187
Disassemble of
water-containing
plate modules
Disassemble 4
screws shown in
the graph with
screwdriver (two
screws on both left
and right), and
remove the
water-containing
plate modules.
Disassembly of fixing plate modules for air sweeping fans
Remark: Make sure the power supply is cut off before disassembling and protect all the parts during disassembly,
especially the connection part of air sweeping fans.
Step Illustration Handling Instruction
Disassembly
of fixing plate
modules for
air sweeping
fans
Disassemble the
screws on both ends
of fixing plate
modules for air
sweeping fans (1 for
both sides) and
remove the fixing
plate modules for air
sweeping fans from
the air deflecting
support.
Disassembly of evaporator components
Remark: Make sure the power supply is cut off and protect the copper tube and aluminum fin. If the time for
disassembly shall be long, put the copper tube under pressurized condition.
Step Illustration Handling Instruction