72
Installation and Maintenance
Service Manual
11.2 Removal Procedure of Outdoor Unit
Warning: Be sure to wait for a minimum of 20 minutes after
turning off all power supplies and discharge the refrigerant
completely before removal.
Procedure Steps
1.Remove big handle
2. Remove top cover
Top cover
Before disassamble
Remove 1 connection screw fixing big
handleand then removethe big handle.
Remove 3 connection screws among
top cover plate, front panel and right
sideplate. Then remove top cover
plate.
Bighandle