User Manual
EM303A General Purpose Inverter
62
F6-08 Operation Time T1 0.0~6000.0 S/min 30.0 ●
F6-09 Operation Time T2 0.0~6000.0 S/min 30.0 ●
F6-10 Operation Time T3 0.0~6000.0 S/min 30.0 ●
F6-11 Operation Time T4 0.0~6000.0 S/min 30.0 ●
F6-12 Operation Time T5 0.0~6000.0 S/min 30.0 ●
F6-13 Operation Time T6 0.0~6000.0 S/min 30.0 ●
F6-14 Operation Time T7 0.0~6000.0 S/min 30.0 ●
F6-15
Speed Cycling
Times
1~10000 1 ●
F6-16
Skip Frequency
Point1
0.00~600.00/0.0~6000.0 Hz 600.00 ●
F6-17 Skip Range 1
0.00~20.00/0.0~20.0
0.00/0.00: Disabled
Hz 0.00 ●
F6-18
Skip Frequency
Point 2
0.00~600.00/0.0~6000.0 Hz 600.00 ●
F6-19 Skip Range 2
0.00~20.00/0.0~20.0
0.00/0.0: Disabled
Hz 0.00 ●
F6-20
Skip Frequency
Point 3
0.00~600.00/0.0~6000.0 Hz 600.00 ●
F6-21 Skip Range 3
0.00~20.00/0.0~20.0
0.00/0.0: Disabled
Hz 0.00 ●
F6-22~ F6-23 Not used
F6-24
Wobbulation
Operation Mode
Ones place: Wobbulation operation
control
0:Auto-operation
1:Terminal Control
Tens place: Wobbulation input mode
0:Wobbulation operation started after
the mid-point reached
1:Start wobbulation operation when its
preset time is up
0 〇
F6-25
Preset Wobbulation
Frequency
0.00~Fmax/0.0~Fmax Hz 0.00 ●
F6-26
Preset Wobbulation
Time
0.00~600.00 S 0.00 ●
F6-27
Upper Limit
Frequency of
Wobbulation
0.00~Fmax/0.0~Fmax Hz 40.00 ●
F6-28
Lower Limit
Frequency of
Wobbulation
0.00~Fmax/0.0~Fmax Hz 20.00 ●
F6-29
Jump Frequency of
Wobbulation
0.00~Fmax/0.0~Fmax Hz 5.00 ●
F6-30
Rising Time of
Wobbulation
0.00~600.00 S/min 0.00 ●
F6-31
Dropping Time of
Wobbulation
0.00~600.00 S/min 5.00 ●