SINMAG SM-402 Mixer
W & P Reedy Pty Ltd 02-9533-9522
www.wpreedy.com.au
Page 12
Trouble Shooting:
Problem Possible Cause Remedy
The SINMAG
SM-402 mixer
does not start
• Not plugged in
• The main switch is off
• Fuse overload at the power board
• The mixer overload has been activated
• Stop button still locked down
• Safety guard open
• Bowl and handle not raised
• Start button not depressed
• Plug in and switch on
• Turn on
• Contact supervisor
• Resets automatically
(10 mins)
• Release by rotating and
pulling
• Close guard
• Pull handle and bowl up
• Press start button
The SINMAG
SM-402 starts
then stops
• The mixers overload has been activated
• Fuse overload at the power board
• Resets automatically
(10mins). If overload
occurs repeatedly contact
supervisor or
W & P Reedy
• Contact supervisor or
W & P Reedy
The SINMAG
SM-402
labours under
load
• Mix too stiff / tight
• Mechanical malfunction
• Loose belts or drive belts
• Review and adjust recipes
• Advise supervisor
• Contact W & P Reedy
service agent.
Electric motor
functions but
planetary does
not turn
• Electrical / Mechanical malfunction • Switch off power at main
switch. Isolate moulder by
removing wall plug.
Attach danger tag to
machine. Contact W & P
Reedy
The SINMAG
SM-402 does
not stop
• Electrical / Mechanical malfunction • Switch off power at main
switch. Isolate mixer by
removing wall plug.
Attach danger tag to
machine. Contact W & P
Reedy