EasyManua.ls Logo

sinmag SM-402 - Trouble Shooting

sinmag SM-402
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINMAG SM-402 Mixer
W & P Reedy Pty Ltd 02-9533-9522
www.wpreedy.com.au
Page 12
Trouble Shooting:
Problem Possible Cause Remedy
The SINMAG
SM-402 mixer
does not start
• Not plugged in
• The main switch is off
• Fuse overload at the power board
• The mixer overload has been activated
• Stop button still locked down
• Safety guard open
• Bowl and handle not raised
• Start button not depressed
• Plug in and switch on
• Turn on
• Contact supervisor
• Resets automatically
(10 mins)
• Release by rotating and
pulling
• Close guard
• Pull handle and bowl up
• Press start button
The SINMAG
SM-402 starts
then stops
• The mixers overload has been activated
• Fuse overload at the power board
• Resets automatically
(10mins). If overload
occurs repeatedly contact
supervisor or
W & P Reedy
• Contact supervisor or
W & P Reedy
The SINMAG
SM-402
labours under
load
• Mix too stiff / tight
• Mechanical malfunction
• Loose belts or drive belts
• Review and adjust recipes
• Advise supervisor
• Contact W & P Reedy
service agent.
Electric motor
functions but
planetary does
not turn
• Electrical / Mechanical malfunction • Switch off power at main
switch. Isolate moulder by
removing wall plug.
Attach danger tag to
machine. Contact W & P
Reedy
The SINMAG
SM-402 does
not stop
• Electrical / Mechanical malfunction • Switch off power at main
switch. Isolate mixer by
removing wall plug.
Attach danger tag to
machine. Contact W & P
Reedy