AUXILIARY OUTPUT
CONNECTION OF THE FLOOR SENSOR
(OPTIONAL)
CONNECT YOUR THERMOSTAT TO THE GT130 GATEWAY OR A COMPATIBLE ZIGBEE SYSTEM
INSTALL YOUR THERMOSTAT
Unlock and lift the
thermostat cover.
Depending on the heating system,
insert each wire into its terminal
and screw firmly. (See connection
layouts outlined in the following
pages.)
Use the provided screws and
wall anchors to fix the
thermostat's base on the wall.
Replace and lock the
thermostat cover.
1
2
4
5
Power up the thermostat.
6
If necessary, mark and drill the
appropriate fastening holes using the
installation template. If needed, use
the wall anchors included.
3
TH1400ZB
Installation Guide
Smart Low Voltage Thermostat (24 Vca)
WIRING LAYOUT
The thermostat provides an auxiliary heating output that
can act as a second stage of heating when controlling
ambient temperature.
If the room temperature is too far from the setpoint or the
main stage of heating has difficulties raising the tempera-
ture, the auxiliary output activates the secondary heating
source to reach the set temperature.
Both outputs can control different types of heating loads
and can be configured in the user settings.
C
W1
R
W2
S1
S 2
120 V
240 V
347 V
24 V
24 Vac
normally open
Valve
Floor sensor
Electric floor heating
Electric baseboard
Electric baseboard
Floor sensor
For use in floor or ambient
mode with floor limit.
Not required for ambient
mode alone.
Electric floor heating with electric
baseboard on the 2nd heating stage
Hot water valve
Electric baseboard
Only for control applications in floor (F) mode or with floor limit.
Sensor
ADD YOUR THERMOSTAT TO THE GT130
GATEWAY AND NEVIWEB
Tap the then select "Add Device"
2
1
If you do not have an account yet,
download the Neviweb app for iOS or
Android to create an account and add
your device.
Follow the steps of the Installation Wizard
3
1 2
Connect all your
thermostats the same way,
by going to the next
closest thermostat.
3
4
Hub
2nd
1st
3rd
Initiate the connectivity session
by pressing the RF signal button
on the GT130 gateway. The
indicator light will start flashing.
Compatible Zigbee gateway:
refer to the installation guide for
the latter.
Connect your thermostat to the network
by pressing briefly and simultaneously
on the and buttons.
On the thermostat display:
Blinks: Connecting
Remains lit: Connected
If the connectivity fails, the
symbol will disappear from the
display. Refer to our Website to
troubleshoot the unit.
When all your devices are connected, close the
connectivity session of your GT130 gateway or
your compatible Zigbee gateway.
Alimentez le thermostat.
Question and Answer IconNeed help?

Do you have a question about the Sinope TH1400ZB and is the answer not in the manual?

Summary

Install Your Thermostat

Unlock and Lift Thermostat Cover

Remove the thermostat cover to access internal components for installation.

Mark and Drill Fastening Holes

Use the installation template to mark and drill holes for secure wall mounting.

Connect Wires and Screw Firmly

Insert wires into terminals and secure them tightly according to wiring layouts.

Fix Thermostat Base to Wall

Secure the thermostat's base onto the wall using the provided screws and anchors.

Replace and Lock Thermostat Cover

Reattach the thermostat cover and lock it into place after installation.

Power Up the Thermostat

Restore power to the thermostat to activate it after installation.

Auxiliary Output Functionality

Floor Sensor Connection

Wiring Layout Diagrams

Add Thermostat to Gateway and Neviweb

Account Creation and App Download

Download the Neviweb app for iOS or Android to create an account.

Initiate Device Addition

Tap to access the device menu and select 'Add Device'.

Follow Installation Wizard

Proceed through the guided steps provided by the Installation Wizard.

Connect Thermostat to Zigbee System

Initiate Gateway Connectivity Session

Press the RF signal button on the GT130 gateway to start pairing.

Connect Thermostat to Network

Press and hold specific buttons on the thermostat to establish network connection.

Connect Additional Thermostats

Add more thermostats by repeating the process for the next closest unit.

Close Gateway Connectivity Session

Finalize the network connection by closing the session on the gateway.

User Settings and Device Parameters

Accessing User Settings

Hold a button for 10 seconds to access the menu for parameter changes.

Temperature Regulation Modes

Select between ambient (A) or floor (F) temperature regulation modes.

Temperature Format Setting

Configure the display to show temperature in Celsius (°C) or Fahrenheit (°F).

Control Mode Selection

Choose between ambient (A) or floor (F) control mode for heating.

Minimum Setpoint Adjustment

Set the lowest acceptable temperature for the heating control.

Maximum Setpoint Adjustment

Set the highest acceptable temperature for the heating control.

Maximum Ambient Temperature Limit (F Mode)

Limit floor heating to prevent exceeding the set ambient temperature.

Maximum Floor Temperature Limit (A Mode)

Limit floor heating to prevent exceeding the set floor temperature.

Minimum Floor Temperature Limit (A Mode)

Maintain a minimum floor temperature for user comfort.

Main Output Cycle Length

Select the appropriate cycle length for the main heating output.

Auxiliary Output Cycle Length

Select the appropriate cycle length for the auxiliary heating output.

Floor Sensor Type Configuration

Specify the resistance (10K or 12K) of the connected floor sensor.

Circulator Pump Anti-Seizure

Enable anti-seizure feature for hydronic systems to prevent pump seizing.

Disconnect Thermostat from Zigbee System

Sinope TH1400ZB Specifications

General IconGeneral
TypeSmart Thermostat
ConnectivityZigbee
Voltage24 VAC
Load TypeHeating and cooling
Temperature Range5°C to 30°C (41°F to 86°F)
DisplayLCD
Control TypeTouchscreen
Power SourceBattery or hardwired
Operating Temperature0°C to 40°C (32°F to 104°F)
Storage Temperature-20°C to 60°C
Temperature Control Accuracy±0.5°C
Operating Humidity5 to 95 %RH
CertificationsCE
CompatibilityZigbee 3.0