- 4 -
5 Port Outline Diagram:
5.1 Port Description
If there are still errors, please replace the control box and call
for customer service.
E09
E11
Positioning signal error
Turn off the machine, please check if the encoder in bad
connection or is too loose. To get it right and turn on. If there
are still errors, please replace the control box and call
for customer service.
E14 Encoder signal error.
Turn off the system power supply, please check motor encoder
connector if loose or fall off, renew to normal then restart
system. If still not work, please replace the motor and notify the
manufacture.
E15
Power module abnormal over current
protection
Turn off the system power supply, and then restart the
machine. If still not work, please replace the control box and
notify the manufacture.
E17
The sewing table safety switch is not in
the correct position
Turn off the system power supply, please check machine head
is open or not, the machine head switch is damage or not.