EasyManua.ls Logo

SKF 086501 - Measures in Response to Malfunctions

SKF 086501
154 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
9. Malfunctions, causes, and remedies
EN
90
9.6 Measures in response to malfunctions
Fault notification Cause Remedy
Empty signal
o Grease reservoir
empty
Fill grease reservoir
No pressure build-up at
pump pressure switch
o Line broken
Inspect lubrication system, replace broken lubrication line if necessary
o Pump motor is
defective
Replace the pump
o Sensor is defective
Replace the sensor
No pressure build-up at
reversing valve
o Blockage of pressure
switch
o Signal line is broken
o Monitoring time
exceeded
Check pressure switch for proper function, replace if necessary
Check signal line for damage, replace if necessary
Adjust the monitoring time
o Sensor is defective
Replace the sensor

Table of Contents

Related product manuals