5SKF TKSA 31 & TKSA 41
1.2 Principle of operation
The TKSA 31/41 uses two measuring units (MU) both provided with a laser diode and a CCD detector.
As the shafts are rotated through 180° any parallel or angular misalignment causes the two laser lines to
defl ect from their initial relative position.
The measurements from the two detectors are used to automatically calculate the misalignment and guide the
user through the vertical (shimming) and horizontal correction steps.
The measurements can be taken according to the 9-12-3 method or with a free measurement method on the
TKSA 41. Measurements can also be taken automatically without action from the user on the Display Unit.
The TKSA 41 can be used with the display fl at on the fl oor or vertical.
The screen orientation will adapt to the display unit orientation.
Results can be saved on a PDF report and exported on a USB stick.